본문

서브메뉴

Realizing the Applications of Nonlinear Encoding in MRI- [electronic resource]
Realizing the Applications of Nonlinear Encoding in MRI - [electronic resource]
Realizing the Applications of Nonlinear Encoding in MRI- [electronic resource]

상세정보

자료유형  
 학위논문파일 국외
최종처리일시  
20240214101922
ISBN  
9798380858946
DDC  
616
저자명  
Froelich, Taylor William.
서명/저자  
Realizing the Applications of Nonlinear Encoding in MRI - [electronic resource]
발행사항  
[S.l.]: : University of Minnesota., 2023
발행사항  
Ann Arbor : : ProQuest Dissertations & Theses,, 2023
형태사항  
1 online resource(118 p.)
주기사항  
Source: Dissertations Abstracts International, Volume: 85-05, Section: B.
주기사항  
Advisor: Garwood, Michael.
학위논문주기  
Thesis (Ph.D.)--University of Minnesota, 2023.
사용제한주기  
This item must not be sold to any third party vendors.
초록/해제  
요약Magnetic Resonance Imaging (MRI) possesses the unique ability to capture a wide range of physiological attributes with high spatial resolution. This flexibility has allowed researchers and medical professionals to not only study, but diagnose, an array of disease states and illnesses that previously required invasive means. However, despite its' tremendous advantages most of the world's population lacks ready access to this diagnostic tool, often having to travel great distances just to reach a scanner. MRI currently faces a severe inequity in both accessibility and utilization due to the high costs associated with obtaining, transporting, and maintaining a traditional scanner. Hence MRI is generally limited to the middle and upper classes in wealthier countries; creating a tremendous need for this diagnostic tool to be disseminated to regions with lower per capita income.The primary goal of this work is to explore several approaches to the challenges of under-utilization and inaccessibility that the field of MRI faces. All of the techniques presented here have shown promise in improving the accessibility of MRI by either eliminating or replacing costly components without sacrificing on the diagnostic quality of the images. The first approach explored the feasibility of employing a low power, nonlinear gradient to perform slice selection and phase refocusing in a traditional spin-echo type sequence. Showing that it is not only possible to image in a permanent hyperboloidal gradient, but also observing the benefits to phase compensation and resolution, thus opening the door to exploring nonlinear encoding fields. The next approach sought to eliminate pulsed B0 gradients in favor of radio-frequency (RF) based gradients. This approached utilized a nonlinear, spatially-varying RF field to encode information in a fast-spin echo sequence. As a proof of concept, only one dimension utilized this approach but the work can be easily extended to 2D. The final approach looked at the logistics of creating and implementing a portable MRI system. This required the design and installation of nonstandard hardware in all aspects of the imaging system; including a novel high temperature superconducting magnet, a multi-channel digital spectrometer, and a multi-channel gradient array capable of creating arbitrary encoding field.
일반주제명  
Medical imaging.
일반주제명  
Physics.
키워드  
Magnetic Resonance Imaging
키워드  
Physiological attributes
키워드  
Radio-frequency
키워드  
Scanner
기타저자  
University of Minnesota Physics
기본자료저록  
Dissertations Abstracts International. 85-05B.
기본자료저록  
Dissertation Abstract International
전자적 위치 및 접속  
로그인 후 원문을 볼 수 있습니다.

MARC

 008240612s2023      us  |||||||||||||||c||eng  d
■001000016935353
■00520240214101922
■006m          o    d                
■007cr#unu||||||||
■020    ▼a9798380858946
■035    ▼a(MiAaPQ)AAI30690911
■040    ▼aMiAaPQ▼cMiAaPQ
■0820  ▼a616
■1001  ▼aFroelich,  Taylor  William.
■24510▼aRealizing  the  Applications  of  Nonlinear  Encoding  in  MRI▼h[electronic  resource]
■260    ▼a[S.l.]:▼bUniversity  of  Minnesota.  ▼c2023
■260  1▼aAnn  Arbor  :▼bProQuest  Dissertations  &  Theses,  ▼c2023
■300    ▼a1  online  resource(118  p.)
■500    ▼aSource:  Dissertations  Abstracts  International,  Volume:  85-05,  Section:  B.
■500    ▼aAdvisor:  Garwood,  Michael.
■5021  ▼aThesis  (Ph.D.)--University  of  Minnesota,  2023.
■506    ▼aThis  item  must  not  be  sold  to  any  third  party  vendors.
■520    ▼aMagnetic  Resonance  Imaging  (MRI)  possesses  the  unique  ability  to  capture  a  wide  range  of  physiological  attributes  with  high  spatial  resolution.  This  flexibility  has  allowed  researchers  and  medical  professionals  to  not  only  study,  but  diagnose,  an  array  of  disease  states  and  illnesses  that  previously  required  invasive  means.  However,  despite  its'  tremendous  advantages  most  of  the  world's  population  lacks  ready  access  to  this  diagnostic  tool,  often  having  to  travel  great  distances  just  to  reach  a  scanner.  MRI  currently  faces  a  severe  inequity  in  both  accessibility  and  utilization  due  to  the  high  costs  associated  with  obtaining,  transporting,  and  maintaining  a  traditional  scanner.  Hence  MRI  is  generally  limited  to  the  middle  and  upper  classes  in  wealthier  countries;  creating  a  tremendous  need  for  this  diagnostic  tool  to  be  disseminated  to  regions  with  lower  per  capita  income.The  primary  goal  of  this  work  is  to  explore  several  approaches  to  the  challenges  of  under-utilization  and  inaccessibility  that  the  field  of  MRI  faces.  All  of  the  techniques  presented  here  have  shown  promise  in  improving  the  accessibility  of  MRI  by  either  eliminating  or  replacing  costly  components  without  sacrificing  on  the  diagnostic  quality  of  the  images.  The  first  approach  explored  the  feasibility  of  employing  a  low  power,  nonlinear  gradient  to  perform  slice  selection  and  phase  refocusing  in  a  traditional  spin-echo  type  sequence.  Showing  that  it  is  not  only  possible  to  image  in  a  permanent  hyperboloidal  gradient,  but  also  observing  the  benefits  to  phase  compensation  and  resolution,  thus  opening  the  door  to  exploring  nonlinear  encoding  fields.  The  next  approach  sought  to  eliminate  pulsed  B0  gradients  in  favor  of  radio-frequency  (RF)  based  gradients.  This  approached  utilized  a  nonlinear,  spatially-varying  RF  field  to  encode  information  in  a  fast-spin  echo  sequence.  As  a  proof  of  concept,  only  one  dimension  utilized  this  approach  but  the  work  can  be  easily  extended  to  2D.  The  final  approach  looked  at  the  logistics  of  creating  and  implementing  a  portable  MRI  system.  This  required  the  design  and  installation  of  nonstandard  hardware  in  all  aspects  of  the  imaging  system;  including  a  novel  high  temperature  superconducting  magnet,  a  multi-channel  digital  spectrometer,  and  a  multi-channel  gradient  array  capable  of  creating  arbitrary  encoding  field.
■590    ▼aSchool  code:  0130.
■650  4▼aMedical  imaging.
■650  4▼aPhysics.
■653    ▼aMagnetic  Resonance  Imaging
■653    ▼aPhysiological  attributes
■653    ▼aRadio-frequency
■653    ▼aScanner
■690    ▼a0574
■690    ▼a0605
■71020▼aUniversity  of  Minnesota▼bPhysics.
■7730  ▼tDissertations  Abstracts  International▼g85-05B.
■773    ▼tDissertation  Abstract  International
■790    ▼a0130
■791    ▼aPh.D.
■792    ▼a2023
■793    ▼aEnglish
■85640▼uhttp://www.riss.kr/pdu/ddodLink.do?id=T16935353▼nKERIS▼z이  자료의  원문은  한국교육학술정보원에서  제공합니다.
■980    ▼a202402▼f2024

미리보기

내보내기

chatGPT토론

Ai 추천 관련 도서


    신착도서 더보기
    최근 3년간 통계입니다.

    소장정보

    • 예약
    • 소재불명신고
    • 나의폴더
    • 우선정리요청
    • 비도서대출신청
    • 야간 도서대출신청
    소장자료
    등록번호 청구기호 소장처 대출가능여부 대출정보
    TF08975 전자도서 마이폴더 부재도서신고 비도서대출신청

    * 대출중인 자료에 한하여 예약이 가능합니다. 예약을 원하시면 예약버튼을 클릭하십시오.

    해당 도서를 다른 이용자가 함께 대출한 도서

    관련 인기도서

    로그인 후 이용 가능합니다.