본문

서브메뉴

Experimental Investigation of Factors Influencing Seasonal Performance of Water-Cooled Chiller and Heat Pump
Experimental Investigation of Factors Influencing Seasonal Performance of Water-Cooled Chi...
Experimental Investigation of Factors Influencing Seasonal Performance of Water-Cooled Chiller and Heat Pump

상세정보

자료유형  
 학위논문 서양
최종처리일시  
20260202105654
ISBN  
9798265452702
DDC  
621
저자명  
Inampudi, Sugun Tej.
서명/저자  
Experimental Investigation of Factors Influencing Seasonal Performance of Water-Cooled Chiller and Heat Pump
발행사항  
[Sl] : University of Illinois at Urbana-Champaign, 2024
발행사항  
Ann Arbor : ProQuest Dissertations & Theses, 2024
형태사항  
166 p
주기사항  
Source: Dissertations Abstracts International, Volume: 87-06, Section: B.
주기사항  
Advisor: Wang, Sophie.
학위논문주기  
Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2024.
초록/해제  
요약Rising cooling needs for the residential and commercial air conditioning sectors and the demand for higher seasonal efficiencies require HVAC&R to handle cooling loads below the design condition. Although several studies exist focusing on a particular compressor capacity modulation strategy, there is no extensive study that explores all these available modulation strategies in the same experimental facility. This study experimentally compared a single speed, a two-stage compressor, tandem combinations of two single-speed compressors, a single speed and two-stage compressor, and a variable-speed compressor using the same R410A water ethylene glycol (WEG) system for cooling application. These modulation strategies were tested according to AHRI Standard 551/591 (2020), and their seasonal performance is given by Integrated Part Load Value (IPLV.SI). A two-stage compressor with lower LMTD at the heat exchangers and a single speed compressor with higher isentropic efficiency have the same performance at one of the part load conditions. Additionally, a single speed compressor with an improved compressor motor had a 3% higher IPLV.SI than a two-stage compressor with the baseline motor. Different methods of interpolation that are available when the capacity is in between two compressor stages of operation were discussed. The tandem combinations with different number of stages had the same seasonal performance, showing that not all the stages available might be useful. The variable speed compressor with the best IPLV.SI was selected to further study the performance under heating application using EU 14825 (2013) standard with constant and variable condenser outlet conditions. For heating application, variable speed compressor with a wider range of modulation was recommended when selecting the compressor for variable condenser outlet temperature conditions while it might not be the best option due to compressor operating envelope limitation when operating with constant condenser temperature outlet. Due to the new restrictions and ongoing phase-down of high GWP refrigerants, there is an increased focus on the amount of refrigerant used. In the current study, the optimum charge was compared for two different scroll compressors: a variable speed compressor and a single speed compressor in the same R410A which is installed with a condenser, receiver and dedicated subcooler. The results showed that COP maximizing charge corresponds to a when some part of the two-phase heat transfer happens in the subcooler and not when the receiver is partially filled as intended. The charge optimization was conducted not only at full load conditions but also at part load conditions to determine if there is any effect of continuous capacity modulation like variable speed compressor on the optimum charge. Optimum subcooling and the improvement potential for compressor which does not have continuous capacity modulation and cannot match the required load without cycling was found to be higher at part load conditions than full load conditions. The effect of operating at peak COP charge on seasonal performance was also analyzed under cooling operation using a variable speed compressor. Although cooling capacity obtained when the system is operating with COP maximizing charge was 6% lower than when operating with typical operating charge, IPLV.SI was 11% higher. Additionally, charge optimization was done for the first time in the same experimental facility with different configurations of the condenser with/without receiver and with/without subcooler to understand the contribution of these components. The abnormal peak in COP corresponding to when the receiver was empty of liquid refrigerant was not observed for any of the three configurations without a dedicated subcooler. This study also provided for the first time insights into how a receiver and dedicated subcooler can be used to not only obtain optimum subcooling but also account for any potential refrigerant leaks by holding additional charge in the receiver. Results indicated that an ideal charge optimization curve can be achieved by sizing the condenser and subcooler to ensure only the optimum subcooling happens in it. The impact of dedicated subcooler and condenser sizing on both charge optimization as well as the system, seasonal performance was also studied. This analysis helped in understanding how these components should be sized and when the diminishing returns occur from oversizing. This work also showed that when the system is operating with enough refrigerant to fill the receiver with saturated liquid refrigerant, using a dedicated subcooler decouples the cooling capacity increment from power consumption increase typically observed with increasing subcooling. Results showed that for the investigated system increasing the dedicated subcooler area beyond 8% of the total available heat rejection area will not yield any additional seasonal performance improvement. Seasonal performance studies usually focus on compressor capacity modulation methods; however, the current study explored the idea of improving the seasonal performance of two compressor modulation techniques: a two-stage and a variable speed compressor with different capacity modulation ranges by using larger condensers in an R410A water ethylene glycol chiller system. The analysis showed that oversizing the heat exchangers has larger benefits with the compressor modulation strategy with lower range. Additionally, the seasonal performance of a two-stage compressor with oversized condenser was higher than a basic single speed compressor with a better motor indicating that oversizing BPHX might yield higher performance than improving the compressor motor efficiency. Due to the high GWP of R410A, there is a focus on replacing it with low GWP refrigerants such as R32 to reduce CO2 emissions. This study also compared the performance when using R32 as a drop-in refrigerant in the two different R410A compressor capacity modulation strategies with comparable cooling capacity. When the refrigerant was changed from R410A to R32, IPLV.SI for variable speed compressor remains relatively constant at 5.5 while it increased from 3.9 to 4.4 for the two-stage compressor. It was hypothesized that low refrigerant flow rate provided by variable speed compressor when matching the load at the lower part load conditions led to refrigerant maldistribution in BPHX and reduced IPLV.SI. Compressors are compared using efficiency and BPHX are evaluated based on their LMTD and pressure drops. It is difficult to compare the contribution of these two to the system COP using traditional first law analysis. Advanced exergy analysis (AEA) can help with this estimation by using exergy destruction as a metric. In the current study, AEA framework was used to analyze the different factors that can impact the system performance and seasonal performance. Three factors included are compressor motor efficiency, condenser size and compressor capacity modulation strategy. AEA showed that optimizing the compressor followed by condenser has the highest potential of improving system performance. Exogenous total exergy destruction dropped by 18% with upgraded compressor while it dropped by 28% with oversized condenser showing that that the condenser has higher impact on the exergy destruction. AEA comparison of a two-stage compressor and a variable speed compressor showed that endogenous exergy destruction of the two-stage compressor is 39% higher indicating that variable speed compressor is more efficient at matching the cooling load. Based on the relative magnitude of avoidable endogenous exergy destruction, upgrading the compressor and condenser would yield higher system performance when using two-stage and variable speed compressors respectively.
일반주제명  
Mechanical engineering
일반주제명  
Engineering
일반주제명  
Thermodynamics
키워드  
Compressor capacity modulation
키워드  
Charge optimization
키워드  
Seasonal performance
키워드  
Advanced exergy analysis
키워드  
Dedicated subcooler
키워드  
Water cooled chiller
기타저자  
University of Illinois at Urbana-Champaign Mechanical Sci & Engineering
기본자료저록  
Dissertations Abstracts International. 87-06B.
전자적 위치 및 접속  
로그인 후 원문을 볼 수 있습니다.

MARC

 008260126s2024        us                              c    eng  d
■001000017361024
■00520260202105654
■006m          o    d                
■007cr#unu||||||||
■020    ▼a9798265452702
■035    ▼a(MiAaPQ)AAI32409648
■035    ▼a(MiAaPQ)124479
■040    ▼aMiAaPQ▼cMiAaPQ
■0820  ▼a621
■1001  ▼aInampudi,  Sugun  Tej.
■24510▼aExperimental  Investigation  of  Factors  Influencing  Seasonal  Performance  of  Water-Cooled  Chiller  and  Heat  Pump
■260    ▼a[Sl]▼bUniversity  of  Illinois  at  Urbana-Champaign▼c2024
■260  1▼aAnn  Arbor▼bProQuest  Dissertations  &  Theses▼c2024
■300    ▼a166  p
■500    ▼aSource:  Dissertations  Abstracts  International,  Volume:  87-06,  Section:  B.
■500    ▼aAdvisor:  Wang,  Sophie.
■5021  ▼aThesis  (Ph.D.)--University  of  Illinois  at  Urbana-Champaign,  2024.
■520    ▼aRising  cooling  needs  for  the  residential  and  commercial  air  conditioning  sectors  and  the  demand  for  higher  seasonal  efficiencies  require  HVAC&R  to  handle  cooling  loads  below  the  design  condition.  Although  several  studies  exist  focusing  on  a  particular  compressor  capacity  modulation  strategy,  there  is  no  extensive  study  that  explores  all  these  available  modulation  strategies  in  the  same  experimental  facility.  This  study  experimentally  compared  a  single  speed,  a  two-stage  compressor,  tandem  combinations  of  two  single-speed  compressors,  a  single  speed  and  two-stage  compressor,  and  a  variable-speed  compressor  using  the  same  R410A  water  ethylene  glycol  (WEG)  system  for  cooling  application.  These  modulation  strategies  were  tested  according  to  AHRI  Standard  551/591  (2020),  and  their  seasonal  performance  is  given  by  Integrated  Part  Load  Value  (IPLV.SI).  A  two-stage  compressor  with  lower  LMTD  at  the  heat  exchangers  and  a  single  speed  compressor  with  higher  isentropic  efficiency  have  the  same  performance  at  one  of  the  part  load  conditions.  Additionally,  a  single  speed  compressor  with  an  improved  compressor  motor  had  a  3%  higher  IPLV.SI  than  a  two-stage  compressor  with  the  baseline  motor.  Different  methods  of  interpolation  that  are  available  when  the  capacity  is  in  between  two  compressor  stages  of  operation  were  discussed.  The  tandem  combinations  with  different  number  of  stages  had  the  same  seasonal  performance,  showing  that  not  all  the  stages  available  might  be  useful.  The  variable  speed  compressor  with  the  best  IPLV.SI  was  selected  to  further  study  the  performance  under  heating  application  using  EU  14825  (2013)  standard  with  constant  and  variable  condenser  outlet  conditions.  For  heating  application,  variable  speed  compressor  with  a  wider  range  of  modulation  was  recommended  when  selecting  the  compressor  for  variable  condenser  outlet  temperature  conditions  while  it  might  not  be  the  best  option  due  to  compressor  operating  envelope  limitation  when  operating  with  constant  condenser  temperature  outlet.                        Due  to  the  new  restrictions  and  ongoing  phase-down  of  high  GWP  refrigerants,  there  is  an  increased  focus  on  the  amount  of  refrigerant  used.  In  the  current  study,  the  optimum  charge  was  compared  for  two  different  scroll  compressors:  a  variable  speed  compressor  and  a  single  speed  compressor  in  the  same  R410A  which  is  installed  with  a  condenser,  receiver  and  dedicated  subcooler.  The  results  showed  that  COP  maximizing  charge  corresponds  to  a  when  some  part  of  the  two-phase  heat  transfer  happens  in  the  subcooler  and  not  when  the  receiver  is  partially  filled  as  intended.  The  charge  optimization  was  conducted  not  only  at  full  load  conditions  but  also  at  part  load  conditions  to  determine  if  there  is  any  effect  of  continuous  capacity  modulation  like  variable  speed  compressor  on  the  optimum  charge.  Optimum  subcooling  and  the  improvement  potential  for  compressor  which  does  not  have  continuous  capacity  modulation  and  cannot  match  the  required  load  without  cycling  was  found  to  be  higher  at  part  load  conditions  than  full  load  conditions.  The  effect  of  operating  at  peak  COP  charge  on  seasonal  performance  was  also  analyzed  under  cooling  operation  using  a  variable  speed  compressor.  Although  cooling  capacity  obtained  when  the  system  is  operating  with  COP  maximizing  charge  was  6%  lower  than  when  operating  with  typical  operating  charge,  IPLV.SI  was  11%  higher.  Additionally,  charge  optimization  was  done  for  the  first  time  in  the  same  experimental  facility  with  different  configurations  of  the  condenser  with/without  receiver  and  with/without  subcooler  to  understand  the  contribution  of  these  components.  The  abnormal  peak  in  COP  corresponding  to  when  the  receiver  was  empty  of  liquid  refrigerant  was  not  observed  for  any  of  the  three  configurations  without  a  dedicated  subcooler.                        This  study  also  provided  for  the  first  time  insights  into  how  a  receiver  and  dedicated  subcooler  can  be  used  to  not  only  obtain  optimum  subcooling  but  also  account  for  any  potential  refrigerant  leaks  by  holding  additional  charge  in  the  receiver.  Results  indicated  that  an  ideal  charge  optimization  curve  can  be  achieved  by  sizing  the  condenser  and  subcooler  to  ensure  only  the  optimum  subcooling  happens  in  it.  The  impact  of  dedicated  subcooler  and  condenser  sizing  on  both  charge  optimization  as  well  as  the  system,  seasonal  performance  was  also  studied.  This  analysis  helped  in  understanding  how  these  components  should  be  sized  and  when  the  diminishing  returns  occur  from  oversizing.  This  work  also  showed  that  when  the  system  is  operating  with  enough  refrigerant  to  fill  the  receiver  with  saturated  liquid  refrigerant,  using  a  dedicated  subcooler  decouples  the  cooling  capacity  increment  from  power  consumption  increase  typically  observed  with  increasing  subcooling.  Results  showed  that  for  the  investigated  system  increasing  the  dedicated  subcooler  area  beyond  8%  of  the  total  available  heat  rejection  area  will  not  yield  any  additional  seasonal  performance  improvement.                        Seasonal  performance  studies  usually  focus  on  compressor  capacity  modulation  methods;  however,  the  current  study  explored  the  idea  of  improving  the  seasonal  performance  of  two  compressor  modulation  techniques:  a  two-stage  and  a  variable  speed  compressor  with  different  capacity  modulation  ranges  by  using  larger  condensers  in  an  R410A  water  ethylene  glycol  chiller  system.  The  analysis  showed  that  oversizing  the  heat  exchangers  has  larger  benefits  with  the  compressor  modulation  strategy  with  lower  range.  Additionally,  the  seasonal  performance  of  a  two-stage  compressor  with  oversized  condenser  was  higher  than  a  basic  single  speed  compressor  with  a  better  motor  indicating  that  oversizing  BPHX  might  yield  higher  performance  than  improving  the  compressor  motor  efficiency.                          Due  to  the  high  GWP  of  R410A,  there  is  a  focus  on  replacing  it  with  low  GWP  refrigerants  such  as  R32  to  reduce  CO2  emissions.  This  study  also  compared  the  performance  when  using  R32  as  a  drop-in  refrigerant  in  the  two  different  R410A  compressor  capacity  modulation  strategies  with  comparable  cooling  capacity.  When  the  refrigerant  was  changed  from  R410A  to  R32,  IPLV.SI  for  variable  speed  compressor  remains  relatively  constant  at  5.5  while  it  increased  from  3.9  to  4.4  for  the  two-stage  compressor.  It  was  hypothesized  that  low  refrigerant  flow  rate  provided  by  variable  speed  compressor  when  matching  the  load  at  the  lower  part  load  conditions  led  to  refrigerant  maldistribution  in  BPHX  and  reduced  IPLV.SI.                        Compressors  are  compared  using  efficiency  and  BPHX  are  evaluated  based  on  their  LMTD  and  pressure  drops.  It  is  difficult  to  compare  the  contribution  of  these  two  to  the  system  COP  using  traditional  first  law  analysis.  Advanced  exergy  analysis  (AEA)  can  help  with  this  estimation  by  using  exergy  destruction  as  a  metric.  In  the  current  study,  AEA  framework  was  used  to  analyze  the  different  factors  that  can  impact  the  system  performance  and  seasonal  performance.  Three  factors  included  are  compressor  motor  efficiency,  condenser  size  and  compressor  capacity  modulation  strategy.  AEA  showed  that  optimizing  the  compressor  followed  by  condenser  has  the  highest  potential  of  improving  system  performance.  Exogenous  total  exergy  destruction  dropped  by  18%  with  upgraded  compressor  while  it  dropped  by  28%  with  oversized  condenser  showing  that  that  the  condenser  has  higher  impact  on  the  exergy  destruction.  AEA  comparison  of  a  two-stage  compressor  and  a  variable  speed  compressor  showed  that  endogenous  exergy  destruction  of  the  two-stage  compressor  is  39%  higher  indicating  that  variable  speed  compressor  is  more  efficient  at  matching  the  cooling  load.  Based  on  the  relative  magnitude  of  avoidable  endogenous  exergy  destruction,  upgrading  the  compressor  and  condenser  would  yield  higher  system  performance  when  using  two-stage  and  variable  speed  compressors  respectively.
■590    ▼aSchool  code:  0090.
■650  4▼aMechanical  engineering
■650  4▼aEngineering
■650  4▼aThermodynamics
■653    ▼aCompressor  capacity  modulation
■653    ▼aCharge  optimization
■653    ▼aSeasonal  performance
■653    ▼aAdvanced  exergy  analysis
■653    ▼aDedicated  subcooler
■653    ▼aWater  cooled  chiller
■690    ▼a0548
■690    ▼a0537
■690    ▼a0348
■71020▼aUniversity  of  Illinois  at  Urbana-Champaign▼bMechanical  Sci  &  Engineering.
■7730  ▼tDissertations  Abstracts  International▼g87-06B.
■790    ▼a0090
■791    ▼aPh.D.
■792    ▼a2024
■793    ▼aEnglish
■85640▼uhttp://www.riss.kr/pdu/ddodLink.do?id=T17361024▼nKERIS▼z이  자료의  원문은  한국교육학술정보원에서  제공합니다.

미리보기

내보내기

chatGPT토론

Ai 추천 관련 도서


    신착도서 더보기
    최근 3년간 통계입니다.

    소장정보

    • 예약
    • 소재불명신고
    • 나의폴더
    • 우선정리요청
    • 비도서대출신청
    • 야간 도서대출신청
    소장자료
    등록번호 청구기호 소장처 대출가능여부 대출정보
    TF18920 전자도서 대출가능 마이폴더 부재도서신고 비도서대출신청 야간 도서대출신청

    * 대출중인 자료에 한하여 예약이 가능합니다. 예약을 원하시면 예약버튼을 클릭하십시오.

    해당 도서를 다른 이용자가 함께 대출한 도서

    관련 인기도서

    로그인 후 이용 가능합니다.